Microcentrifuges are mainly used in molecular biology laboratories for Plasmid extraction; Nucleic acid purification; Pre-sequencing processing and other applications including extracting of DNA/RNA samples,sedimentation biological components, biochemical and chemical analyses of microsamples.
| Models | |||||
| Palm150 | Pulse operation for fast and convenient quick spins | ||||
| Speed up to 15000rpm (15100×g) | |||||
| Brushless DC motor drive quickly to the target speed | |||||
| Smooth and quiet operation (noise ≤54dB) | |||||
| Automatic lid-lock and over-speed detection | |||||
| Passed rigorous explosion-proof test, certified with CE,cTÜVus, FCC | |||||
| Micro150R | • Electronic Magnetic door locking system - the lid can be closed with one hand soft touch | ||||
| • Precooling, the compressor automatically starts cooling as long as the set temperature is lower than the ambient temperature | |||||
| • Sound indicator at the end of running. | |||||
| • Temperature range -20℃ to 40℃ | |||||
| • Short pre-cooling time of only 7minutes from room temperature to 4℃ | |||||
| • Up to 9 program storage capacity | |||||
| • 3-layer sealed rotors ensure safe centifugation | |||||
| • High-strength aluminum alloy rotor can be fully autoclavable at 121℃ | |||||
| • Rotor imbalance detection alarm | |||||
| • Adjustable acceleration/deceleration at 9 levels allows gentle braking at low speed for better separation | |||||
| • Five rotors with 0.2mL, 0.5mL, 1.5mL, 2mL and 5mL centrifuge tubes/ PCR tubes capacity | |||||
| • An external condensation tank prevents water accumulation within centrifuge chamber | |||||
| Micro150 | • Patent special double cooling air design ensures fast cooling of the rotor and low energy consumption | ||||
| • 3-layer sealed rotors ensure safe centifugation | |||||
| • Brushless motor drive, maintenance free | |||||
| • Safety features include door interlock; excessive speed and temperature detection; automatic self-diagnostics | |||||
| • Outstanding aluminum alloy rotors fully autoclavable at 121℃ temperature and high pressure disinfection | |||||
| • Five rotors are optional complete with 24 places 1.5/2.0mL tubes,5.0mL, 0.2mL and 0.5mL tubes with adapters | |||||
| Specifications | Palm150 | Micro150R | Micro150 |
| Max. Speed | 15000rpm(500-15000rpm), increment: 100rpm | 15,000rpm (200-15,000rpm), increment:100rpm | 15000rpm(200-15000rpm), increment:10rpm |
| Max. RCF | 15100×g, increment: 100×g | 21,380×g, step: 100×g | 21380×g, increment:10×g |
| Rotor Capacity | 0.2mL/0.5mL/1.5mL/2mL×12 | 1.5/2mL ×24,0.2/0.5mL ×36,PCR-8 strips×4,5mL ×12,5mL×18 | 1.5/2mL ×24,0.2/0.5mL ×36, PCR-8 strips×4,5mL ×12,5mL×18 |
| Temperature setting | (-20℃-40℃) | ||
| Run Time | 30sec-99min/Continuous | 30s-99 min; HOLD (continuous running) | 30sec-99min/Continuous |
| Acceleration/Braking time | 11s↑/9s↓ | 25s↑25s↓ | 25s↑25s↓ |
| Driving Motor | Brushless DC motor | Brushless DC motor | Brushless DC motor |
| Safety Performance | Door interlock, Over-speed detection, Over-temperature detection, Automatic internal diagnosis | Dual door lock, over-speed detection,over-temperature detection with Internal diagnosis system. | Dual door interlock,Over-speed detection,Automatic internal diagnosis |
| Power Requirements | Single-phase, AC100V-240V, 50Hz/60Hz, 3A100W | Single-phase,200-240V, 50Hz/60Hz,500W 100V-120V,50Hz/60Hz,500W | Single-phase, AC200V-400V,50Hz/60Hz, 5A,AC100V-120V,50Hz/60Hz, 8A 200W |
| Noise Level | ≦54dB | ≦56dB | ≦64dB |
| Dimension[W×D×H] | 255×245×140mm | 332×553×283mm | 280×364×266mm |
| Weight | 6kg | 30kg | 12kg |
| Certification | EMC CE FCC ICES cTÜVus CB | CE cTÜVus FCC | CE cTÜVus FCC MCA |
| Other functions | Speed/RCF switch,Short-time run function,sound-alert function | Rotation speed/RCF switchover,inching operation, running processindicator,sound alert,Adjustable acceleration/deceleration at 9 levels program storage capacity. | Speed/RCF switch; Short-time run function; sound-alert function |