The instrument was developed according to the regulations of the inspection device in the injection clarification inspection rules and judgment standards. It is suitable for the clarity detection of various injections, large infusions, and bottled liquid medicines.
Features:
Clarity detector CD-2 and CD-3
The traditional timing dial is removed, and it is changed to chip integrated control, full touch buttons, easy to operate, and the service life of the instrument is increased by 3 times
Users can calibrate the illuminance of the instrument by themselves according to the standard illuminance meter, that is, the self-calibration function is added.
Increased the length of the bottom whiteboard, enabling side-by-side detection of infusion bags
The detection lamp is upgraded to a grade A refined pharmaceutical inspection lamp, and the service life is twice that of the traditional lamp
Increase voltage stability control circuit, detection optical system eliminates stroboscopic, adjustable illumination, improves visual resolution, and reduces visual fatigue.
Using a digital electronic illuminance meter, the reading is intuitive, stable, and reliable, the detection time can be set arbitrarily, and it has a sound and light alarm function.
Clarity detector CD-2A
It can directly detect the clarity of raw materials for injection and injections.
The instrument adopts a full-color LCD touch screen for operation control, and has four-level authority management and audit trail functions, which fully meets the data integrity requirements of GMP, and is an effective instrument for liquid consistency evaluation.
Clarity detector CD-2 Technical parameter
Power: 20W
Lamp tube: 20W (special grade A refined tricolor fluorescent lamp, electronic ballast)
Illumination range: 1000—6000LX
Time limit range: 1-99S can be set arbitrarily
Dimensions: 703mm×175mm×513mm
Clarity detector CD-3
Illumination range: 1000—6000LX
Power source: AC220V±10% 50Hz
Power: 22W
Lamp tube: 20W (Special grade A refined tri-color fluorescent lamp, electronic ballast)
Time limit range: 1-99S can be set arbitrarily
Dimensions: 703mm×345mm×513mm
Weight: 18Kg
Clarity detector CD-2A Technical parameter
Measuring principle: 90° scattered light
Light source wavelength: LED light source wavelength 860nm
Measuring range: 0~10NTU, 10~100NTU, 100~1000NTU, automatic range
Resolution: 0.01NTU(0-10NTU), 0.1NTU(10.0-100), 1NTU(100-1000NTU)
Indication error: ±2%F.S
Repeatability: ≤0.5%
Zero drift: ±0.5%F.S
Instrument calibration: 1~5 points automatic calibration
Interface: USB
Ambient temperature: room temperature -65°C
Power supply: 220V, 50Hz