Bag-in/Bag-out Safety Filter Enclosures (BIBO) are safety filtration systems typically connected to exhaust systems to prevent the leakage of hazardous contaminants. Their fully enclosed bag-in/bag-out design provides a safe and reliable method for filter replacement, effectively preventing secondary air contamination.
BIBO filtration cabinets are primarily used for exhaust ventilation in pharmaceutical production facilities, supply/exhaust ventilation for isolation equipment, supply/exhaust ventilation in biosafety laboratories, exhaust ventilation in hospital isolation zones, and industrial chemical gas emissions.
Air Tightness
The enclosure features a fully welded construction with standard pressure resistance of ±3kPa. Prior to shipment, each unit undergoes air tightness testing at a pressure no less than 2.5kPa. Complies with GB 50346-2011 and JG/T 497-2016 requirements, and has obtained third-party inspection certification.
![]()
![]()
Protective Sealing Bag
Each access door of the bag-in/bag-out filter enclosure is equipped with a protective bag approximately 2m in length, complete with a full set of drawstrings and safety belts. The premium model includes two internal gloves for convenient operation. Filter replacement occurs within the protective bag, preventing gas inside the enclosure from contacting the external environment, thereby safeguarding both operators and the surrounding area.
![]()
![]()
Optional Filter Stages
Single-stage filtration features only a high-efficiency filter. Multi-stage filtration options include pre/medium-efficiency filtration
Sections, chemical filtration sections, activated carbon filtration sections, dual HEPA filtration sections, etc. Filtration stages can be customized as required.
Installation Methods
Standard installation is horizontal. Vertical or other configurations are available based on site conditions. Series connection of units extends gas residence time within the enclosure. Rain shelters can be provided for outdoor installations.
| Model | IBIBO-HNH | IBIBO-1CH | IBIBO-4CH |
| External Dimensions (HxWxD) | 708x403x540 mm | 708x708x794 mm | 1416x1416x834 mm |
| Maximum Airflow | 1700 CMH/1000 CFM | 3400 CMH/2000 CFM | 13600 CMH/8000 CFM |
| HEPA Filter Section | H14 (EN1822) 610x305x292 mm - 1 pcs |
H14 (EN1822) 610x610x292 mm - 1pc |
H14 (EN1822) 610x610x292 mm - 4 pcs |
| Pre/Medium Efficiency Filter Section | N.A | G4 (EN779) | F8 (EN779) |
| Activated Carbon Gas Filter Section | N.A | N.A | VOC |
| Enclosure Material | Cold-rolled steel (electrostatic powder coating)/SUS 304 | Cold-rolled steel (electrostatic powder coating) /SUS304 | Cold-rolled steel (electrostatic powder coating) / SUS304 |
| PAO Sampling Port | SUS 304, φ10 mm | SUS 304, φ10 mm | SUS304, φ10 mm |
| Differential Pressure Gauge/Sensor | Optional accessory, 0~750 Pa | Optional accessory, 0~750 Pa | Optional accessory, 0~750 Pa |
| HEPA Filter PAO Scanning Section | Optional accessory, automatic or manual | Optional accessory, automatic or manual | Optional accessory, automatic or manual |