BOD incubator

The BOD incubators of the ZXSD-series are designed to meet a variety of advanced experimental needs, ranging

from BOD determination to incubation of micro-organism cultures, preservation of samples, Drosophila incubation and determination of enzymatic activities. All these applications require precise and constant temperature control. Each of the four models has a wide temperature range from ambient -18 °C (minimum 4°C) to 65 °C and can be operated at a single user defined temperature, but can also be programmed with up to 9 different temperature segments within a time frame. (18 steps). The (cooling) compressor runs continuously and the control are done through a solenoid valve for more precise temperature control if lower than ambient temperatures are required.


P.I.D. microprocessor ensures the precision of temperature control under both fixed value mode and program mode.

Large blue LCD display for temperature diagram, easy readout for program control.

Three-dimensional heating system ensures fast response, and high uniformity of±1.0℃@37℃.

Sound cooling system with CFC free refrigerant.

Automatic defrosting: only minimal ice formation and very low heat discharge into working area occurs the unit can continue operating when defrosting.

3 steps adjustable fan speed, offering more precisely controlled environment of incubations, without concerns of media or samples drying out.

Real-time electronic timer from 0 to 999 minutes.

Password protection of all parameters against unauthorized access.

Non-volatile memory retains pre-set parameters in case of power interruption.

Triple safety protections for samples, incubator and environment.

Independent device for over temperature, high current flow and electric leakage.

Model ZXSD-B1090 ZXSD-B1160 ZXSD-B1270 ZXSD-B1430
Volume (L) 90 160 270 430
Door Type Outer door with observation window, and heat resistance glass inner door
Temperature Range (°C) 4 to 65
Temperature Accuracy     (°C) 0.1
Temperature Uniformity     (°C) ±1.0 @37℃
Cooling System Automated, with R134A Refrigerant
Alarm Enabled
Timer (min) 0-999
Settings Digital
Display LCD
Grids Included 2 (Max 11) 2 (Max 15) 2 (Max 18) 2 (Max 25)
Grid Size (mm) (WxD) 310x356 410x456 513x556 555x656
Inner Dimensions (mm) (WxDxH) 400x410x550 500x500x650 600x600x750 700x645x950
Exterior Dimensions (mm) (WxDxH) 550x555x1280 630x740x1380 750x840x1480 840x880x1680
Packing Dimensions (mm) (WxDxH) 620x625x1440 700x810x1540 820x810x1640 910x950x1840
Net/Gross Weight (kg) 68/108 98/145 130/180 180/220
Power (W) 710 860 950 1350
Standard Configuration Fluorescent lamp, 50 mm Test Port
Options Built-in Printer, UV LAMP, RS-232 interface
Electricity 220-240V 50/60 Hz
Approval CE, ISO